Vertiv Discontinued the Albér CLU 

We Have Your Replacement  

  The DV Power BLU series is the direct technical replacement for the Albér CLU -- available now through ProgUSA.

Get a Quote

What the Discontinuation Means for You

Vertiv has ended production of the Albér CLU with no announced replacement. That means no new units, no long-term parts supply, and no upgrade path from Vertiv. If your battery capacity testing program depends on CLU equipment, now is the time to plan your transition -- before a failed unit creates a compliance or maintenance gap.

The BLU Series -- Built for This Job  

  The DV Power BLU is an active current load unit that performs the same battery discharge and capacity testing function as the Albér CLU. It covers the same voltage ranges, pairs with the BVS system to replace the BCT-2000 controller, and ships in a portable form factor -- no fixed installation required. ProgUSA has been a DV Power distributor for over 20 years and stocks units for quick delivery.

Get a Quote

Utility Substation

48V / 125V / 250V

BLU300C + BVS

Full CLU and BCT-2000 replacement for substation battery banks

Battery Energy Storage (BESS)

1,100 – 1,200V DC

BLU1350D

High-voltage discharge testing for utility-scale storage systems



Telecom / DC Power

24V – 48V

BLU220T + BVR22

Cell voltage monitoring and capacity testing for telecom battery strings

Data Center

800V DC

BLU1100D or BLU1350D

Native 800V DC support for next-generation data center architectures

Albér CLU vs. DV Power BLU300C -- Side-by-Side Comparison

Vertiv Albér CLUDV Power BLU300C
TechnologyPassive resistor bankActive current control -- precise discharge regulation
Voltage Range48V, 125V, 250V substation systems48V, 125V, 250V substation systems
Form FactorStationary, fixed installation -- 400 to 1,000 lbs.Portable, field deployable -- fraction of the weight
ScalabilityFixed capacity per unit; multiple heavy units requiredParallel BLU units or add BXL modules for higher discharge current
Controller / DataBCT-2000 controller (also discontinued)BVS -- Battery Verification System (full data logging/capacity reports)
Test AccuracyResistor-based, fixed load stepsConstant current throughout discharge for accurate capacity results
AvailabilityDISCONTINUEDIn Stock -- Available Now
Service & SupportNone -- Vertiv has ended service and parts supplyDV Power factory support + ProgUSA US-based application support
Vendor HistoryVertiv / Albér -- product line discontinuedDV Power -- 30 years in battery test equipment

Contact ProgUSA for product selection guidance: progusa.net  |  407-332-8678

20+

Years -- ProgUSA

Electrical test and measurement distribution across North America

30

Years -- DV Power

Purpose-built battery test equipment, nothing else

7 ​

Target Segments

From power plants to data centers -- we know your application

3+1

Years Warranty

All the protection you need to stay up and running reliably



Get a Quote  

Tell us your voltage system and how many units you need. We will turn around a quote within one business day.


Contact Us



Spec Sheet

Full technical specifications for the DV Power BLU300C and BVS Battery Verification System -- the direct replacement for the Albér CLU and BCT-2000.

BLU-C-SeriesBVS-B Series



Talk to a Rep

Have a specific setup or a tight timeline? Call us directly. We stock DV Power equipment and can move fast.

Call: 407-332-8678